LF-autoPP
Features:
★ Automatic, after the addition of reagents, the instrument automatically completes blocking of the membrane, the incubation of primary antibodies and second antibodies and washing without manual operation.
★ *High throughput: at most12 incubation tanks working simultaneously, max incubation membranes are 24 pcs.
★ Different incubation tanks are controlled by different independent programs for good repeatability of experiment, each incubation tank is placed with different primary antibodies and secondary antibodies and blocking buffer.
★ *The incubation tank is removed and installed bysliding in and out of incubation bay, which is flexible and convenient to operate, and greatly reduce the volatilization of antibodies and antibody activity.
★ *Four different modes: constant temperature mode, ladder temperature mode, room temperature mode, and washing mode. Samples in different incubation tanks under constant temperature mode and room temperature mode are incubated anachronically.
★ *Each incubation tank consists of a divisible combination of tanks for primary antibody and secondary antibody. easy for antibodyaddition and cycle.
★ *Peltier temperature control system, support 2-40℃ temperature adjustment to incubate at 4°c overnight, or to incubate at 37℃ quickly. Under ladder temperature mode, there is no need to set temperature for blocking, primary antibody incubation, and secondary antibody incubation.
★ Antibody dosage: 2~6ml (XS incubation tank),3~8ml (Sincubation tank),6~18ml(M incubation tank),9~20ml(Lincubation tank).
★ *Automatic cycling of primary and secondary antibodies, cycle rate of up to 95% repeated use up to 10 times.
★ *Pipette workstation type for addition of primary antibody and secondary antibody, pipette is cleaned automatically befor eeach pipette toavoid cross contamination.
★ The amount of each washing buffer is adjusted according to requirements of each experiment.
★ *Different sizes of incubation tanks for selection: 15x85mm(max 12 pcs),30×80mm(max 12 pcs),64×80mm (max6 pcs),98x80mm(max 4 pcs), and different sizes of incubation tanks can be used together.
★ After the program of experiment is finished, the pipelines are cleaning automatically to remove the residual reagent.
★ Capacitive touch screen is easy for users, support the storage of 50 groups of programs, the user interface
provides real-time observation ofeach incubationtank.
★ After incubation, the washing buffer is retained in the incubation tank to maintain low speed vibration to keep the membrane moist
★ Compatible with reagent consumables from other brands.
★ Support adjustment of oscillation speed, range 60-110 RPM.
★ Running status and remaining time of each incubation shows on the user interface during the running.
★ There will besound prompt when key steps and programs are ended.
★ Compact structure, occupying small space, only 58×36×32cm.
★ weight:27kg